Learn about our Engaged Experts The human body and its immune and inflammatory mechanisms can create an aggressive environment for metallic implants resulting in implant rejection and failure Gilbert, Corrosion, ;73 12 In vitro testing of small implants is typically performed per ASTM Fb to mitigate these risks. While this testing helps determine implant susceptibility to corrosion, it does not take into account the effects of cells, proteins, and other biological effects that implants will experience in vivo. The standard provides a test method for conducting cyclic forward and reverse potentiodynamic polarization measurements on whole devices in their final form and finish.

Author:Vumi Dogor
Country:Iran
Language:English (Spanish)
Genre:Photos
Published (Last):9 July 2011
Pages:430
PDF File Size:13.18 Mb
ePub File Size:16.11 Mb
ISBN:336-9-36064-114-2
Downloads:68247
Price:Free* [*Free Regsitration Required]
Uploader:Gogami



More F During the selection process of a material for use as an implantable device, testing the corrosion resistance of the material is an essential step; however, it does not necessarily provide critical data regarding device performance. The results of this corrosion test conducted in artificial physiological electrolytes can provide useful data for comparison of different device materials, designs, or manufacturing processes.

However, note that this test method does not take into account the effects of cells, proteins, and so forth, on the corrosion behavior in vivo.

Scope 1. Examples of device types that may be evaluated by this test method include, but are not limited to, vascular stents, ureteral stents Specification F , filters, support segments of endovascular grafts, cardiac occluders, aneurysm or ligation clips, staples, and so forth. These small devices should be tested in their entirety. The upper limit on device size is dictated by the electrical current delivery capability of the test apparatus see Section 6.

No other units of measurement are included in this standard. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

33N10 DATASHEET PDF

Medical Device Corrosion Testing per ASTM F2129

More F During the selection process of a material for use as an implantable device, testing the corrosion resistance of the material is an essential step; however, it does not necessarily provide critical data regarding device performance. The results of this corrosion test conducted in artificial physiological electrolytes can provide useful data for comparison of different device materials, designs, or manufacturing processes. However, note that this test method does not take into account the effects of cells, proteins, and so forth, on the corrosion behavior in vivo. Scope 1. Examples of device types that may be evaluated by this test method include, but are not limited to, vascular stents, ureteral stents Specification F , filters, support segments of endovascular grafts, cardiac occluders, aneurysm or ligation clips, staples, and so forth. These small devices should be tested in their entirety.