FRIEDLAND SA5 PDF

Shakakree But gains it back again is ssa5 does support wired zones and will work with an ansaphone which was a massive bonus for me. If you can hide this box behind a wall or in a cupboard that will make it more resistant to tampering. It supports both a wired bell as well as a wireless bell. It is a shame that you need to call them though simply because the manual does not warn you about zone 10 or the jamming detection sensitivity with the bell. Far easier to install than a triedland alarm I had previously fitted.

Author:Meztitaur Voodoomuro
Country:Mozambique
Language:English (Spanish)
Genre:Health and Food
Published (Last):8 June 2019
Pages:254
PDF File Size:4.66 Mb
ePub File Size:8.67 Mb
ISBN:447-3-77594-149-2
Downloads:72015
Price:Free* [*Free Regsitration Required]
Uploader:Goltigor



Secondly check that the user code is not the default If this is the case it is possible that the system may have had a power cut, the backup batteries are old and depleted and consequently the system has lost its memory or at least part of. If this is the case, then the P1 jumper is incorrectly set to on inside the control panel next to the DC power socket. Remove the DC power jack, then remove and disconnect one of the back-up batteries. Set jumper link P1 to the ON position. Reconnect the power supply jack.

The Control Panel will now reconfigure itself with all factory default settings. Reconnect and replace the back-up battery. Reset jumper link P1 into the OFF position. Close the Control Panel cover and refit the fixing screws. A tell tale sign of this would be if you are pressing commands on the remote but getting no response e.

The solution would be to get the siren back into operating mode by pressing and holding the arm button for six seconds until you get a single short beep. If the red LED light flashes repeatedly when first installing, then this means the battery has just been fitted please wait a couple of minutes for it to settle down and initiate. If the red LED light flashes every 30 seconds - this is a low battery indicator in this detector please change the battery.

It must be connected with a modem lead and not the standard BT-RJ11 lead.

PT2272 PDF

FRIEDLAND SA5 PDF

Secondly check that the user code is not the default If this is the case it is possible that the system may have had a power cut, the backup batteries are old and depleted and consequently the system has lost its memory or at least part of. If this is the case, then the P1 jumper is incorrectly set to on inside the control panel next to the DC power socket. Remove the DC power jack, then remove and disconnect one of the back-up batteries. Set jumper link P1 to the ON position.

IGNACIO INDIO FIGUEREDO LOS CAUJARITOS PDF

Friedland Spares

.

Related Articles